Thorough verification of leak prevention performance of stainless steel piping using composite repair.

Not only carbon steel, but also stainless steel piping can be installed! Verification of leak prevention effectiveness.

We examined the leak prevention effect when applying primer to stainless steel piping. A pressure test was conducted under the same conditions to compare the leak prevention effects of carbon steel piping and stainless steel piping. It was found that applying primer to stainless steel piping, which cannot undergo surface treatment with electric tools (Bristol Blaster), can demonstrate leak prevention effects. 【Test Piece Details】 ■ Shape: Connecting 1B piping only with a composite layer (PE sheet used for shaping) ■ Number of Layers: 2 layers ■ Surface Treatment ・ Carbon Steel Piping: Electric tools ・ Stainless Steel Piping: Primer *For more details, please download the PDF or feel free to contact us.

  • コンポジットリぺアによるステンレス鋼配管の漏れ止め性能を徹底検証2.JPG
  • Repair Agent

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Thorough verification of leak prevention performance under harsh construction conditions using composite repair.

We offer services that can be expected to restore the strength of reduced meat piping, stop leaks, and improve textile effects!

The state of the 3B piping is broken, which is considered a missing part. We will consider repairs under the condition that the required durability of the equipment is 1 year, and we created two patterns of test specimens, conducting pressure tests on each. The required number of layers based on the design for a durability of 1 year is as follows: if we can achieve 7 layers with a 50mm overlap and 5 layers with a 150mm overlap, we demonstrated sufficient leak-stopping effect even under harsh construction conditions. [Verification Results] ■ Overlap 50mm - Number of layers: 7 - Result (MPa): 3.0 (leakage occurred at 3.0MPa during pressurization) ■ Overlap 150mm - Number of layers: 5 - Result (MPa): 5.0 (no leakage at 5.0MPa) * Testing was concluded at 5.0MPa due to the risk of piping breakage. * For more details, please download the PDF or feel free to contact us.

  • コンポジットリペアによる過酷な施工条件での漏れ止め性能を徹底検証2.JPG